Description
Rotating the camera in place can start a LOD0-only emitter 1,750 m away. This reproduces with the stock medium smokestack, which has UseFrameEvent enabled by default. When the camera turns back toward the smokestack, the newly emitted particles are still alive.
Steps to reproduce
The attached ZIP automates these steps. Extract it and run Run-Repro.cmd on a Windows Steam installation. It saves the per-emitter counts in Results/run-…/particle-counts.txt.
Place two copies of Prefabs/Particles/Smoke/Smoke_Smokestack_Medium.et at the same position. Leave Use Frame Event enabled on the first copy and clear it on the second.
Face the effects from 1,750 m. Observe the active particle counts for Smoke_Main (LOD0 only) and Smoke_Long_01_LOD2 (LOD2 only).
Without moving or zooming, turn 180° away and hold for nine seconds. Turn back and observe the counts. Finally, move to 15 m and face both effects to verify that both LOD0 emitters work.
Expected result
At 1,750 m, the LOD0-only emitter should stay inactive when the camera turns away. The effect can continue updating off-screen at its distant LOD.
Actual result
While facing the smokestack, the LOD2-only layer was active. The LOD0 count was zero both at screen center and 86 pixels inside the left edge.
After a direct 180° turn, the FRAME copy had one live LOD0 particle at 0.5 seconds and five at 9 seconds. Each particle lives at most four seconds, confirming fresh emission behind the camera. After turning back, the count took 3.5 seconds to reach zero.
The VISIBLE copy stayed at zero LOD0 particles throughout the distant test. At 15 m, both copies emitted LOD0 particles.
Test environment
Arma Reforger 1.9.0.37 on Windows x64, Steam build 26266485, engine build 193322. Reproduced in both the regular and diagnostic Steam clients at 3840 × 2160 with a fixed 74° vertical field of view.